TECNIPUL Composites
HOME   |   CATALOGUES   |   CONTACT
CATALÀ   |   CASTELLANO   |   FRANÇAIS

Products - COMPOSITES - TOLERANCE



Dimensional tolerances for pultruded profiles



In the manufacturing of our GRP Profiles, we apply the following tolerances, which can be modified according to the client’s needs.
UNE EN ISO 13706-2.

PROPERTIES TOLERANCE
Thickness of open and closed profile walls

Nominal dimensions (mm)

THICKNESS S S1
0 a 2 ± 0,15 ± 10%
2 a 5 ± 0,20 with minimum
de ± 0,30
5 a 10 ± 0,35
  ± 0,45
Cross directional flatness

Tolerance
T < 0,008 x B mm
Profile height and width of flange
Nominal dimensions (mm)
A y B ± 0,5 with minimum ± 0,20 mm and maximum ┴ 0,75 mm
Size of angle
Tolerance
α ± 1,5º
Straightness
Tolerance (B and H are overall breadth and height dimensions)
D < 0,002 × L2 for sections with B or H < 50 mm
D < 0,001 × L2 for sections with B or H ≥ 50 and < 100 mm
D < 0,000 5 × L2 for sections with B or H ≥ 100 mm
where D and L are in metres.
Twist
Tolerance
V < 1,5° per metre maximum for thickness < 5 mm
V < 1,0° per metre maximum for thickness ≥ 5 mm
Cutting length: -0 + 15 mm
Perpendicularity : ± 1,5º


TECNIPUL Composites
Tecnipul S.L. - Ctra. de Pedrafita s/n, 08281 - Els Prats de Rei (Barcelona)
Tel. +34 93 869 91 33 - Fax +34 93 869 91 16 - tecnipul@tecnipul.com
Legal Notice - Sitemap - Cookies Policy - www.tadipol.com - Web design Anunzia
Standard GRP Profiles - GRP Client Profiles - GRP Gratings and Coverings - GRP Structures
Quality TUV